The Use of Active Personal Dosemeters in Interventional Workplaces in Hospitals: Comparison between Active and Passive dosemeters worn simultaneously by Medical Staff - IRSN - Institut de radioprotection et de sûreté nucléaire Accéder directement au contenu
Article Dans Une Revue Radiation Protection Dosimetry Année : 2020

The Use of Active Personal Dosemeters in Interventional Workplaces in Hospitals: Comparison between Active and Passive dosemeters worn simultaneously by Medical Staff

Filip Vanhavere
  • Fonction : Auteur
  • PersonId : 1094630
Elefhteria Carinou
  • Fonction : Auteur
  • PersonId : 1094631
Isabelle Clairand
  • Fonction : Auteur
  • PersonId : 1057472
Francesca de Monte
  • Fonction : Auteur
  • PersonId : 1094633
Paolo Ferrari
  • Fonction : Auteur
  • PersonId : 1091488
Merce Ginjaume
  • Fonction : Auteur
  • PersonId : 1094635
Hrvoje Hršak
  • Fonction : Auteur
  • PersonId : 1094636
Oliver Hupe
  • Fonction : Auteur
  • PersonId : 1094637
Zeljka Knezevic
  • Fonction : Auteur
  • PersonId : 1094638
Una O’connor
  • Fonction : Auteur
  • PersonId : 1094639
Marta Sans Merce
  • Fonction : Auteur
  • PersonId : 1094640
Sandra Sarmento
  • Fonction : Auteur
  • PersonId : 1094641
Alain Savary
  • Fonction : Auteur
  • PersonId : 1094642

Résumé

Medical staff in interventional procedures are among the professionals with the highest occupational doses. Active personal dosemeters(APDs) can help in optimizing the exposure during interventional procedures. However, there can be problems when using APDs during interventional procedures, due to the specific energy and angular distribution of the radiation field and because of the pulsed nature of the radiation. Many parameters like the type of interventional procedure, personal habits and working techniques, protection tools used and X-ray field characteristics influence the occupational exposure and the scattered radiation around the patient. In this paper, we compare the results from three types of APDs with a passive personal dosimetry system while being used in real clinical environment by the interventional staff. The results show that there is a large spread in the ratios of the passive and active devices.
Fichier non déposé

Dates et versions

hal-03183071 , version 1 (26-03-2021)

Identifiants

Citer

Filip Vanhavere, Elefhteria Carinou, Isabelle Clairand, Olivera Ciraj-Bjelac, Francesca de Monte, et al.. The Use of Active Personal Dosemeters in Interventional Workplaces in Hospitals: Comparison between Active and Passive dosemeters worn simultaneously by Medical Staff. Radiation Protection Dosimetry, 2020, 188 (1), pp.22-29. ⟨10.1093/rpd/ncz253⟩. ⟨hal-03183071⟩
48 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More