Signal-to-Noise Ratio of CABRI Hodoscope: Monte Carlo Calculation Versus Experiments - IRSN - Institut de radioprotection et de sûreté nucléaire Accéder directement au contenu
Article Dans Une Revue IEEE Transactions on Nuclear Science Année : 2022

Signal-to-Noise Ratio of CABRI Hodoscope: Monte Carlo Calculation Versus Experiments

Jacques Di Salvo
  • Fonction : Auteur
  • PersonId : 1128260
Salvatore Mirotta
  • Fonction : Auteur
  • PersonId : 1071134
Vincent Chevalier
  • Fonction : Auteur
  • PersonId : 1071128

Résumé

The CABRI experimental pulse reactor is devoted to the study of Reactivity Initiated Accidents (RIA), for the purpose of the CABRI International Program (CIP), managed by the French Radioprotection and Nuclear Safety Institute (IRSN). CABRI’s hodoscope equipment detects the fast neutrons emitted during a power pulse by a tested rod, positioned inside a dedicated test loop reproducing either sodium reactor or Pressurized Water Reactor (PWR) conditions. One of the most important parameter measured by the hodoscope detectors is the Signal-to-Noise Ratio (SNR), characterizing the fraction of neutrons directly coming from the test rod (“signal”) over neutrons coming from the core (“noise”). In this article, the method used to calculate the SNR using a 2D model of CABRI, with the MCNP6.2 Monte Carlo code, will be detailed. Comparisons between the calculated and measured SNR for different configurations are in quite good agreement. Another parameter of interest is the so-called “scattering coefficient”, which corresponds to the fraction of neutrons coming from the test rod and being scattered between their birth and their detection. This parameter is used to enhance the analysis of the fuel displacement that may happen during the power transient. To estimate this coefficient, an innovative method using a combination of different options available in MCNP6.2 has been used. Computed coefficients shows a slight discrepancy with the measurements. Finally, sensitivity of the SNR and scattering coefficient to technological parameters and nuclear data libraries is discussed

Mots clés

Fichier principal
Vignette du fichier
TNS_SignalToNoise Ratio_PostPrint.pdf (717.51 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

irsn-04113900 , version 1 (01-06-2023)

Licence

Paternité

Identifiants

Citer

Jacques Di Salvo, Salvatore Mirotta, Vincent Chevalier. Signal-to-Noise Ratio of CABRI Hodoscope: Monte Carlo Calculation Versus Experiments. IEEE Transactions on Nuclear Science, 2022, 69 (4), pp.648-655. ⟨10.1109/TNS.2022.3150069⟩. ⟨irsn-04113900⟩

Collections

IRSN PSNRES SEREX
22 Consultations
25 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More